What is on the Devices tab?

Devices shows a site's data loggers and every device of the installation, with the data logger that reads it. For a solar park these are inverters, meters and sensors; for a battery the PCS, containers and racks.

Why it matters

A device without a data logger sends no data, so it gets no figures and no alarms. Here you see at once which data logger delivers, when its latest package came in and which devices are still Niet gekoppeld (not linked).

What you see

At the top

Part What it shows
Data loggers The number of data loggers of the site, with "on this asset"
Linked devices Devices with a data logger, next to all devices of the site, such as "55 / 57"
Latest package When the latest package of the first data logger came in, with how it arrives below it (S3, HTTPS push). Otherwise No package received yet
Fetching first data… Only for a battery with a linked data source that has no data yet. It goes away once the first data is in

Installation

A solar park from the configurator shows the Installation card: the same diagram as on the Installation tab.

Part What it does
Structure Grid connection, groups, inverters, sensors and meters as a diagram, with DC/AC, model, kWp and status per inverter
Communication Which data source reads which device
Table The inverters in a table
Make default Keeps the chosen view as your default. When it reads This is your default view, it already is
Show MPPTs Only in Structure and for a park with fewer than 15 inverters: shows the MPPTs under each inverter
Zoom In, Zoom Out, Fit View Zoom the diagram in or out, or fit the whole diagram on screen
Search and status filters In Table, and in Communication with 15 or more devices: search and filter on Deviations, OK or No status

Click an inverter to open its page, or a data source for the page of that data logger.

Data loggers

One card per data logger:

Part What it shows
Name and status Connected, Configured, Fetch failed, Removed from park configuration or Not configured
Connector and serial number Such as "SMA Data Manager M · serial number —"
Linked devices How many devices hang on this data logger
Mock logger (simulated) Only for a simulated data logger
Delivery Every how many minutes a package comes, and by which route: "Delivers a package every 5 min via S3 to …"
Open datalogger Opens the data logger's page
Add data logger Only for a site without a park configuration, for an Admin or Operator

Installation devices

A table with all devices of the site, 8 per page.

Part What it shows or does
Search devices Searches every column
Connection: all Filters on one data logger, or on Niet gekoppeld
Export button CSV or Excel (.xlsx) of the rows the filter shows
Inverter The device's name. The column is called this, but it also lists meters, sensors and battery parts
Model, Serial number, Manufacturer From the configuration; "—" when empty
Connection The data logger that reads the device, or Niet gekoppeld. This value is shown in Dutch
Previous, Next Page through; on the left it reads "1–8 of 57"

Click a row with a data logger to open that data logger's page. When the table is empty it reads "No devices yet. Add a datalogger first, then link inverters."

Who sees what

  • The tab is for Admin, Operator and Viewer. A customer does not see it.
  • For a site from the configurator, Devices sits among the other tabs and everything is read-only. You change it with Configure asset, in the configurator.
  • For a site without a park configuration, Devices is the third step under Configure asset, after General and Technical. An Admin or Operator can add data loggers there, also with Add with the agent.

How to do it

  1. Open Assets and choose the site. Open in Alpha
  2. Choose the Devices tab. Not among the tabs? Choose Configure asset and then Devices.
  3. Check Linked devices to see whether everything has a data logger.
  4. Pick Niet gekoppeld under Connection: all to see which devices are still loose.
  5. Choose Open datalogger or click a row to look at the data logger.
  6. Want to keep the list? Choose the export button and then CSV or Excel (.xlsx).
  7. Does the site need another data logger and has it no park configuration? Choose Add data logger, fill in Connector type, Name and, if needed, Serial number and Administration URL, and choose Create data logger. The page of the new data logger opens.